The reason exhaust pipes are insulated in unconditioned spaces your attic is because they carry warm and moist air from your home to outside.
Exhaust vent pipes in attic should be insulated and vented.
In our neck of the woods vermont it is required by code to protect the vent stack from freezing.
No you cannot vent your bathroom exhaust fan into the attic.
Just as is the case with insulation in other parts of your home you should regularly inspect and maintain the insulation on your duct work.
Of course all penetrations where drainage or vent pipe goes through walls especially into attic should be sealed around the pipe to prevent infiltration.
It really is a design choice.
The solution properly insulate the vent ducts.
A cold duct allows condensation of moist indoor air leading to drips from the exhaust fan.
Your attic is not a temperature controlled environment is never the same temperature as your living space and generally closer to the temperature outside.
However since the 2009 edition of the irc attics can be designed to be either vented or unvented.
Otherwise the exhaust duct gets too cold when it runs through the attic.
The best exhaust fan venting is through smooth rigid ducts with taped joints and screwed to a special vent hood.
If the insulation around your vent hood duct work becomes waterlogged because of a roof leak or similar problem the insulation s effectiveness will be compromised.
Ventilating attic spaces is often viewed as a technical requirement for steep slope roof assemblies as well as a building code requirement.
Our photo above shows a long routing of bath vent fan ducts across an attic floor to an exit at the building soffit or eaves and the condensation of moisture in such vent lines.
Although fiberglass may not burn it can melt contribute to a fire and the speed at which it spreads.
Duct already wrapped in insulation at home centers.
You should never exhaust the bathroom fan directly into the attic.
Does bathroom vent piping need to be insulated.
Hot air exhaust vents located at the peak of the roof allow hot air to escape.
Insulating around a furnace exhaust pipe.
You can find 4 in.
We insulate the bath vent ductwork to minimize the condensation that will otherwise occur as warm moist bathroom exhaust air passes through cool ductwork in the building attic or roof cavity.
Now that you have safely sealed the air leaks around the furnace exhaust you can work on insulating your attic space.
Horizontal runs are covered with insulation bats in the attic usually.
Intake vents located at the lowest part of the roof under the eaves allow cool air to enter the attic.
Fiberglass insulation cannot just butt up to the vent pipe touching it.