There are also additional requirements where the door is the final exit point of a building.
Fire exit door requirements nz.
The new zealand building code nzbc includes requirements for fire doors in the acceptable solutions c as1 to c as6.
There should be no locks or catches.
Ceilings of exit routes must be at least 7 feet 6 inches high.
The door should open in the direction of evacuation.
Key locks on exit doors in a commercial building retail and food outlets.
The nfpa emergency exit door requirements code states there is a maximum travel distance allowed to find an exit.
We work closely with specifiers and builders to ensure new zealand construction projects get the fire doors they need to satisfy regulations aesthetic considerations and budget constraints.
Exit routes must support the maximum permitted occupant load for each floor served and the capacity of an exit route may not decrease in the direction of exit route travel to the exit discharge.
Self closing the nzbc requires a fire door set to be self closing.
Seals edges of a fire door have fire rated seals.
If there is a fire in the area where occupants are they are already being exposed to smoke fire and heat.
An exit is permitted to have only those openings necessary to allow access to the exit from occupied areas of the workplace or to the exit discharge.
Revoked on 1 july 2018 by regulation 36 of the fire and emergency new zealand fire safety evacuation procedures and evacuation schemes regulations 2018 li 2018 96.
The new fire and emergency new zealand act 2017 and the fire and emergency nz fire safety evacuation procedures and evacuation schemes regulations 2018 both describe.
An exit access must be at least 28 inches wide at all points.
Exit doors must not be locked barred or blocked there can be a management system in place where doors need to be locked due to people being under care or supervision.
Behind every fire door we manufacture is immense technical knowledge that helps you to get exactly the right fire doors for your project.
The acceptable solutions require fire doors to comply with nzs 4520 fire resistant door sets ref.
Jamb an essential and purpose built part of a fire door set.
Fire doors are assigned a fire resistance rating frr from the results of fire testing to as1530 4.
Exits must be kept clear of obstacles at all times.
Anatomy of a fire door.
An opening into an exit must be protected by a self closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system.
Self latching the nzbc requires a fire door set to be self latching.
The same requirements as above will apply to a fire exit door.
This access to exit requirements seeks to minimize occupants exposure to these and other hazards.